Disponibilidad | non separatamente | |
según la Norma | EIA-TIA 568A | |
CARACTERISTÍCAS CONSTRUCTIVAS | ||
Conductor interno | Ø mm | 0,51 |
material | Cu | |
Dieléctrico | Ø mm | 0,90 |
material | PE | |
CARACTERISTÍCAS MECÁNICAS | ||
Peso del cobre | kg/km | 14,3 |
Peso del cable | kg/km | 17,7 |
Min radio de curvatura x 1/n | mm | 20/40 |
CARACTERISTÍCAS ELÉCTRICAS | ||
Impedancia | Ohm | 100±5@100 MHz |
Capacidad mutua (@800Hz) | pF/m | 48 |
Coeficiente de Velocidad | % | 67 |
Atenuación (a 20°C) | ||
a 1 MHz | dB/100m | 1,9 |
a 10 MHz | dB/100m | 6,0 |
a 20 MHz | dB/100m | 8,5 |
a 31,2 MHz | dB/100m | 10,7 |
a 62,5 MHz | dB/100m | 15,7 |
a 100 MHz | dB/100m | 19,8 |
NEXT | ||
a 1 MHz | dB | 71,0 |
a 10 MHz | dB | 56,0 |
a 20 MHz | dB | 51,0 |
a 31,2 MHz | dB | 49,0 |
a 62,5 MHz | dB | 44,0 |
a 100 MHz | dB | 41,0 |
Atenuación de Coppia | dB | > 45 |
Resistencia cc conductor | Ohm/km | 95,0 |
Resistencia de bucle | Ohm/km | 190,0 |
Tensión aislamiento funda (CC, 1 min) | kV | 1,0 |
Cables sin rivestimiento