RG Ref. | RG 6+ | |
Class CPR acc. to UE 305/2011 (DoP) | Fca | |
Availability | on demand | |
Application | Exterior and Underground Installation | |
acc. to Standard | EN50117-10-2 | |
CEI-UNEL 36762 | ||
Reaction to Fire | EN50575 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 1,13 |
material | Cu | |
Dielectric | Ø mm | 4,80 |
material | PEG | |
Film Foil Laminate | material | Cu/Pet |
Braid | material | Cu |
Braid Optical Coverage | % | 59 |
Diameter over Braid | Ø mm | 5,30 |
Outer Sheath | Ø mm | 7,3 |
material | PE | |
PHYSICAL DATA | ||
Copper Content | kg/km | 20,5 |
Cable Weight | kg/km | 47,5 |
Min bending radius x 1/n | mm | 35/70 |
Max.Tensile Strength | N | 150 |
ELECTRICAL DATA | ||
Impedance | Ohm | 75±3@200 MHz |
Capacitance (@1kHz) | pF/m | 52 ± 2 |
Velocity Ratio | % | 85 |
Attenuation (at 20°C ) | ||
at 5 MHz | dB/100m | 1,5 |
at 10 MHz | dB/100m | 2,1 |
at 30 MHz | dB/100m | 2,9 |
at 50 MHz | dB/100m | 3,8 |
at 200 MHz | dB/100m | 7,9 |
at 300 MHz | dB/100m | 9,7 |
at 470 MHz | dB/100m | 12,0 |
at 690 MHz | dB/100m | 14,5 |
at 1000 MHz | dB/100m | 17,9 |
at 1750 MHz | dB/100m | 24,8 |
at 2150 MHz | dB/100m | 27,3 |
at 2400 MHz | dB/100m | 29,1 |
at 3000 MHz | dB/100m | 33,0 |
Structural return loss (SRL) | ||
at 5 - 470 MHz | dB | >30 |
at 470 - 1000 MHz | dB | >28 |
at 1000 - 2000 MHz | dB | >26 |
at 2000 - 3000 MHz | dB | >22 |
Transfer Impedance (Zt) | Class | B |
5 - 30 MHz | mOhm/m | < 11 |
Screening Attenuation (SA) | Class | A |
at 30 - 1000 MHz | dB | >85 |
at 1000 - 2000 MHz | dB | > 80 |
at 2000 - 3000 MHz | dB | > 65 |
DC Conductor Resistance inner/outer | Ohm/km | 18,0 / 14,8 |
Loop resistance | Ohm/km | 32,8 |
Sheat Insulation voltage (spark test) | kV | 8,0 |
Maximum current (Ieff) | A | 8 |
DISTRIBUTION AND TRUNK COAXIAL CABLES (CATV SYSTEMS)