Cables without Outer Sheath LAN640SG

Legend
Legend
Availability in stock
acc. to Standard EIA-TIA 568-B-2
ISO/IEC 11801 2° ed.
IEC 61156-5
EN 50173
EN 50288-6-1
CONSTRUCTION DATA
Inner Conductor Ø mm 0,57
material Cu
Dielectric Ø mm 1,05
material PE
PHYSICAL DATA
Copper Content kg/km 18,5
Cable Weight kg/km 41,0
Min bending radius x 1/n mm 35/70
ELECTRICAL DATA
Impedance Ohm 100±15@1 - 100 MHz
Ohm 100±22@100 - 250 MHz
Capacitance of Twisted Pair (@800Hz) pF/m 48
Velocity Ratio % 67
Attenuation (at 20°C )
at 1 MHz dB/100m 1,8
at 10 MHz dB/100m 5,4
at 20 MHz dB/100m 7,7
at 31,2 MHz dB/100m 9,6
at 62,5 MHz dB/100m 13,7
at 100 MHz dB/100m 17,4
at 155,5 MHz dB/100m 21,9
at 200 MHz dB/100m 25,0
at 250 MHz dB/100m 28,1
NEXT
at 1 MHz dB 100,0
at 10 MHz dB 80,0
at 20 MHz dB 70,0
at 31,2 MHz dB 65,0
at 62,5 MHz dB 60,0
at 100 MHz dB 60,0
at 155,5 MHz dB 55,0
at 200 MHz dB 55,0
at 250 MHz dB 50,0
Coupling Attenuation dB > 45
DC Conductor Resistance Ohm/km 80,0
Loop resistance Ohm/km 160,0
Sheath Insulation Voltage (DC, 1 min) kV 1,0
Cables without Outer Sheath