CONSTRUCTION
DATA
 

11/50FC

17/73FC

22/99FC

27/11FC

RG11FC

   

CATV11
CATV11AP

Inner conductor  
dia mm
Cu
1,13
Cu
1,63
Cu
2,20
Cu
2,70
FeCu
1,63
Cu
1,63
Dielectric  
dia mm
PEG
4,80
PEG
7,20
PEG
9,90
PEG
11,50
PEG
7,20
PEG
7,20
Screen:
film foil laminate
foil coverage
 
 
%
 
CuPet
100
 
CuPet
100
 
CuPet
100
 
CuPet
100
 
Al2
100
 
Al2S
100
braid
braid coverage
 
%
dia mm
Cu
61
5,40
Cu
65
7,80
Cu
55
10,50
Cu
52
12,20
Al
73
7,93
CuSn
65
7,84
Flooding compound filling    PJ PJ PJ PJ PJ PJ
Outer sheat  
dia mm
PE
7,60
PE
10,10
PE
12,70
PE
15,00
PE
10,30
PE
10,1x17
Minimum bending radius:
single/repeated bendings
 
mm
 
50
 
100
 
150
 
200
 
100
 
100
              p10sym_star.gif (98 bytes)rope FeZn 7x0,80 breaking strength 500 Kg
ELECTRICAL DATA
             
Impedance Ohm   75+/-2,5   75+/-2,5   75+/-2,5   75+/-2   75+/-2,5       75+/-2,5
Capacitance pF/m 52+/-2 53+/-2 55+/-2 53+/-2 53+/-2 53+/-2
Velocity ratio % 85 84 82 85 84 84
Attenuation (at 20°C):
at MHz 5
 
dB/100m
 
1,2
 
1,0
 
0,7
 
0,6
 
0,9
 
0,9
at MHz 50 dB/100m 3,8 2,3 1,9 1,7 2,9 2,7
at MHz 200 dB/100m 7,8 5,4 4,2 3,4 5,5 5,6
at MHz 470 dB/100m 12,1 8,4 6,6 5,6 8,8 8,8
at MHz 862 dB/100m 16,8 12,0 9,8 7,9 12,2 12,3
at MHz 1000 dB/100m 18,3 13,3 11,1 8,7 13,5 13,5
at MHz 1350 dB/100m 21,4 15,7 13,2 10,4 15,9 15,9
at MHz 1750 dB/100m 24,6 17,7 15,8 12,3 18,6 17,3
at MHz 2050 dB/100m 26,9 19,4 17,7 13,3 20,5 18,7
at MHz 2150 dB/100m 27,6 19,9 18,2 13,9 21,0 19,7
Structural Return Loss (SRL)
30-470 MHz
 
 
dB
 
   >23
 
  >23
 
>23
 
 >26
 
 >23
 
 >23
470-862 MHz dB >20 >20 >20 >23 >20 >20
862-2150 MHz dB >18 >18 >18 >21 >18 >18
Screening Effectiveness
30-1000 MHz
 
dB
 
>75
 
>75
 
>75
 
>75
 
>80
 
>80
Inner conductor dc resistance Ohm/km 18 8,7 5 3,2 38 8,7
Outer conductor dc resistance Ohm/km 15 11,5 10 7,3 12 11,5
Sheath spark testing kV 8,0 8,0 8,0 8,0 8,0 8,0
Copper weight Kg/km 22,6 39,7 58,3 83 - 34,9
Cable weight Kg/km 52,5 89,5 132,2 181,1 77,1 81     131
PACKING: 
unit lenght
 
m
 
500
 
500
 
500
 
500
 
500
 
500
model No. 4 4 4 5 4 4
Specification conformity:              
EN 50117 (CATV network)   YES YES YES YES YES YES
CEI 12-15 (MATV systems)   YES YES YES YES YES YES
CEI 46-13 (CATV network) YES, Class 8 6 5 4 6 6